TM 55-1560-307-13&P
n. Fuel manifold is equipped with unisex dry break
couplings.
o. System is equipped with vent lines which will fit
either CH-47D model aircraft.
p. Fuel transfer pump system can operate with an
external APU generator, the aircraft's APU, or the
aircraft's main generators (engines have to be running
when using main generators).
q. Tanks may be configured with separate roller
assemblies when internal cargo handling system (highs)
is not installed on aircraft.
1-11. LOCATION AND DESCRIPTION OF MAJOR
COMPONENTS. Refer to Figure 1-1.
1-12. EQUIPMENT DATA. For equipment data, refer
to Table 1-1.
Table 1-1. Equipment Data
System Nomenclature ............................................................................................ Extended Range Fuel System (ERFS)
Part Number ......................................................................................................................................85SDSCC-D-0007-2
Manufacturer ...............................................................................................................Corpus Christi Army Depot (CCAD)
Tank (four each)
Weight, Empty ....................................................................................................................................................... 500 lbs
Weight, Full ......................................................................................................................................................... 3770 lbs
Capacity, Operational ............................................................................................................................................. 580 gal
Length.............................................................................................................................. ...................................60 inches
Width ................................................................................................................................................................. 73 inches
Height ................................................................................................................................................................ 52 inches
Control Panel Box FMCP
Length ................................................................................................................................................................ 33 inches
Width .................................................................................................................................................................... 7 inches
Height ................................................................................................................................................................. 25 inches
Weight .................................................................................................................................................................... ..59 lbs
Power Supply ................................................................................................................................................28 ± 0.3 V dc
System Installation Data
Time to Install System ............................................................................................................................... .4 men, 3 hours
Time to Remove System ............................................................................................................................ 4 men, 3 hours
Change 2