RED   LIGHT   ON   FWD   OR   AFT   TROOP   WARNING   BOX OR  RED  TROOP  JUMP  LTS  LIGHT  DO  NOT COME   ON   BRIGHT   (Continued)
RED   TROOP   JUMP   LTS   LIGHT   DOES   NOT   GO   DIM

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  798    799    800    801    802  803  804    805    806    807    808  
T M     5 5 - 1 5 2 0 - 2 4 0 -T 9-16.9 9-16.9   RED   LIGHTS   ON   FWDANDAFTTROOP   WARNING BOXES  DO  NOT  GO  DIM FAULT   ISOLATION   PROCEDURE INITIAL   SETUP Personnel    Required: 68F10   Aircraft   Electrician Applicable   Configurations: All References: TM   55-1520-240-23 Tools: Electrical  Repairer’s  Tool  Kit, NSN   5180-00-323-4915 Multimeter Equipment   Condition: TM   55-1520-240-23: Electrical  Power  On Hydraulic   Power   Off Materials: None END  OF  TASK 9 - 2 94