GREEN LIGHT ON FWD OR AFT TROOP WARNING BOX OR TROOP JUMP LTS LIGHT DO NOT COME 9-16.11 ON BRIGHT (Continued)
GREEN   TROOP   JUMP   LTS   LIGHT   DOES   NOT   GO   DIM

TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
  802    803    804    805    806  807  808    809    810    811    812  
T M     5 5 - 1 5 2 0 - 2 4 0 - T 9-16.12  GREEN  LIGHTS  ON  FWD  AND  AFT  TROOP  WARNING BOXES DO NOT GO DIM FAULT   ISOLATION   PROCEDURE INITIAL   SETUP Applicable   Configurations: All Tools: Electrical   Repairer’s   Tool   Kit, NSN    5180-00-323-4915 Multimeter Materials: None Materials: None Personnel    Required: 68F20   Aircraft   Electrician References: TM    55-1520-240-23 Equipment   Condition: Battery  Connected Electrical   Power   On Hydraulic   Power   Off 9-16.12 END  OF  TASK 9-298