LH FUEL PUMP CONT AUX AFT CIRCUIT NOT STAY CLOSED (cont)
LH FUEL PUMP CONT MAIN AFT CIRCUIT BREAKER WILL NOT STAY CLOSED (Continued)

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  59    60    61    62    63  64  65    66    67    68    69  
TM  55-1520-240-T 10-2.9 LH FUEL PUMP CONT MAIN AFT CIRCUIT BREAKER WILL NOT STAY CLOSED 1O-2.9 FAULT  ISOLATION  PROCEDURE INITIAL SETUP Applicable    Configurations: All Tools: Electrical  Repairer’s  Tool  Kit, NSN    5180-00-323-4915 Multimeter MateriaIs: None Personnel   Required: Aircraft  Electrician  (2) References: TM   55-1520-240-23 Equipment  Condition: TM   55-1520-240-23: Battery Connected Electrical  Power  On Hydraulic Power Off Side Acoustical Blanket Removed Between Sta 320  and  360 10-56 GO TO NEXT PAGE