LH FUEL PUMP CONT MAIN AFT CIRCUIT BREAKER WILL NOT STAY CLOSED (Continued)
LH  FUEL  PUMP  CONT  MAIN  FWD  CIRCUIT  BREAKER  WILL  NOT  STAY  CLOSED  (Continued)

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  61    62    63    64    65  66  67    68    69    70    71  
TM  55-1520-240-T 10-2.10 LH FUEL PUMP CONT MAIN FWD CIRCUIT BREAKER WILL NOT STAY CLOSED 10-2.10 FAULT  ISOLATION  PROCEDURE INITIAL   SETUP Applicable    Configurations: All Tools: Electrical  Repairer’s  Tool  Kit, NSN   5180-00-323-4915 Multimeter Materials: None Personnel   Required: Aircraft Electrician (2) References: TM   55-1520-240-23 Equipment  Condition: TM   55-1520-240-23: Battery Connected Electrical  Power  On Hydraulic Power Off Side Acoustical Blanket Removed Between Sta 320  and  360 10-58 GO TO NEXT PAGE Change 3