RH FUEL PUMP AUX AFT CIRCUIT BREAKER WILL NOT STAY CLOSED (Continued)
RH FUEL PUMP CONT AUX AFT CIRCUIT BREAKER WILL NOT STAY CLOSED (Continued)

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  77    78    79    80    81  82  83    84    85    86    87  
10-2.16 RH FUEL PUMP CONT AUX AFT CIRCUIT BREAKER WILL NOT STAY CLOSED FAULT  ISOLATION  PROCEDURE INITIAL   SETUP Applicable  Configurations: All Tools: Electrical Repairer’s Tool Kit, NSN    5180-00-323-4915 Multimeter Materials: None Personnel  Required: 68F10 Aircraft Electrician 68F20 Aircraft Electrician References: TM   55-1520-240-23 Equipment  Condition: TM    55-1520-240-23: Battery  Connected Electrical Power On Hydraulic  Power  Off Side Acoustical Blanket Removed Between Sta 320 and 360. 10-2.16 GO TO NEXT PAGE 10-70