TM  55-1520-240-1 10-2.17  RH  FUEL  PUMP  CONT  MAIN  AFT  CIRCUIT  BREAKER  WILL  NOT  STAY  CLOSED 10-2.17 FAULT  ISOLATION  PROCEDURE INITIAL  SETUP Applicable    Configurations: All Tools: Electrical  Repairer’s  Tool  Kit, NSN   5180-00-323-4915 Multimeter Materials: None Personnel   Required: Aircraft  Electrician  (2) References: TM   55-1520-240-23 Equipment  Condition: TM   55-1520-240-23: Battery Connected Electrical  Power  On Hydraulic Power Off Side Acoustical Blanket 320  and  360 Removed Between Sta 10-72 Change 3 GO TO NEXT PAGE