RH FUEL PUMP CONT AUX FWD CIRCUIT BREAKER WILL NOT STAY CLOSED (Continued)
LEFT OR RIGHT SIDE AUX PRESS LIGHTS DOES NOT COME ON 10-2.20 WHEN PRESSED TO TEST (Continued)

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  85    86    87    88    89  90  91    92    93    94    95  
TM   55-1520-240-T 10-2.20 LEFT OR RIGHT SIDE AUX PRESS LlGHTS DOES NOT COME ON WHEN PRESSED TO TEST 10-2.20 FAULT   ISOLATION   PROCEDURE INITIAL SETUP Applicable   Configurations: All Tools: Electrical Repairer’s Tool Kit, NSN   5180-00-323-4915 Multimeter Materials: None Personnel  Required: 68F20 Aircraft Electrician References: TM   55-1520-240-23 Equipment   Condition: TM   55-1520-240-23 Battery  Connected Electrical Power On Hydraulic  Power  Off GO TO NEXT PAGE 10-78