APU  DOES  NOT  MOTOR  WHEN  APU  SWITCH  IS  SET  TO  START (CONTINUED)
APU   DOES   NOT   STOP. ESU   BITE   INDICATES

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  649    650    651    652    653  654  655    656    657    658    659  
TM   55-1520-240-T 15-2.11  APU  ON  CAPSULE  GOES  OUT  (APU  SHUTS  DOWN) WHEN  APU  CONT  CIRCUIT  BREAKER  OPENED 15-2.11 FAULT  ISOLATION  PROCEDURE INITIAL  SETUP Personne/   Required: Aircraft   Electrician APU  ON  CAPSULE  GOES  OUT  (APU  SHUTS  DOWN) WHEN  APU  CONT  “EMERG”  CIRCUIT  BREAKER  OPENED Applicable    Configurations: All References: TM    55-1520-240-23 Tools: Electrical  Repairer’s  Tool  Kit. NSN   5180-00-323-4915 Multi  meter Equipment    Condition: TM    55-1520-240-23: Battery   Disconnected Electrical   Power   Off Hydraulic   Power   Off Materials: None APU  ON  CAPSULE  GOES  OUT  (APU  SHUTS  DOWN) WHEN  APU  CONT  “NORM”  CIRCUIT  BREAKER  OPENED END OF TASK Change 8 15-41