APU  ON  CAPSULE  GOES  OUT  (APU  SHUTS  DOWN) WHEN  APU  CONT  CIRCUIT  BREAKER  OPENED
APU DOES NOT STOP.  ESU BITE INDICATES (cont)

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  650    651    652    653    654  655  656    657    658    659    660  
T M    5 5 - 1 5 2 0 - 2 4 0 -T 15-2.12   APU   DOES   NOT   STOP. ESU   BITE   INDICATES FAULT  ISOLATION  PROCEDURE INITIAL  SETUP References: TM    55-1520-240-23 TM    55-2835-205-23 Applicable    Configurations: All Equipment    Condition: TM   55-1520-240-23: Battery   Connected Electrical  Power  On Hydraulic   Power   Off Tools: Aircraft   Mechanic’s   Tool   Kit. NSN   5180-00-323-4692 Electrical  Repairer’s  Tool  Kit. NSN   5180-00-323-4915 Multimeter General   Safety   Instructions: Materials: Cloth   (E120) Tape  (E385) All   regulations   and   instructions handling   fuels   shall   be   strictly observed. Personnel    Required: Aircraft   Electrician Medium   Helicopter   Repairer 15-42 Change  8