RIGHT  CROSSFEED  FUEL  VALVE  LIGHT  DOES  NOT COME  ON  DURING  PRESS-TO-TEST  (Continued)
CROSSFEED  FUEL  VALVE  HANDLE  IS  NOTAT  OPEN WITH CROSSFEED FUEL VALVES SWITCH AT OPEN  (Continued)

TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
  28    29    30    31    32  33  34    35    36    37    38  
TM   55-1520-240-T 10-1.14  CROSSFEED  FUEL  VALVE  HANDLE  IS  NOT  AT  OPEN  WITH CROSSFEED  FUEL  VALVES  SWITCH  AT  OPEN 10-1.14 FAULT   ISOLATION   PROCEDURE INITIAL   SETUP Applicable   Configurations: All Tools: Electrical  Repairer’s  Tool  Kit, NSN   5180-00-323-4915 Multimeter Materials: None Personnel    Required: 68F20   Aircraft   Electrician References: TM   55-1520-240-23 Equipment   Condition: TM   55-1520-240-23: Battery    Connected Electrical  Power  On Hydraulic   Power   Off 10-28