Google+
Facebook
LinkedIn
Twitter
Digg
StumbleUpon
Home
Download PDF
Order CD-ROM
Order in Print
Figure 9-50. Test Equipment Kit (Cross Reference Chart) (Sheet 2 of 2)
ACIWBDR Wiring Repair Set Permanent Repair Capabilities (One Hour/One Flight) (Continued)
TM-1-1520-240-BD Army CH-47D Heilcopter (NSN 1520-01-088-3869) (EIC:RCD) Manual
Page Navigation
172
173
174
175
176
177
178
179
180
181
182
TM 1-1520-240-BD
Table 9-5. ACMI/BDR Wiring Repair Set Permanent Repair Capabilities (One Hour/One Flight)
TYPE OF REPAIR
COMPONENT TO USE
WIRE OR CABLE SIZE
UNSHIELDED PRIMARY WIRE
CRIMP SPLICE FOR WIRE
20, 22, 24,16, 18 12,14
SPLICING AND REPAIR
RATED 105°C OR BELOW
CRIMP SPLICE FOR WIRE
20, 22, 24, 16, 18 12, 14
RATED 125°C OR ABOVE
WIRE REPAIR SEGMENT FOR
20, 22, 24, 16,18 12,14
WIRE RATED 125°C OR ABOVE
SHIELD CABLE SPLICING
SPLICE FOR SHIELDED CABLE
20, 22, 24, 16, 18 12,14
RATED 125°C OR ABOVE
SHIELD CABLE REPAIR
20, 22, 24,16, 18
SEGMENT (FOR UP TO 9-INCH
DAMAGED LENGTH)
CABLE SHIELD TERMINATION
SHIELD TERMINATOR FOR TIN-
055 - .085 JACKET O.D.
OR SILVER-PLATED SHIELDS
085 - .170 JACKET O.D.
OVER .170 JACKET O.D.
SHIELD TERMINATOR FOR
UP TO .125 TOTAL INSULATION
NICKEL-PLATED SHIELDS
DIAMETER
(INCLUDING VERMILLION)
.125 - .200 TOTAL INSULATION
DIAMETER
WIRE OR SHIELDED CABLE
PRIMARY WIRE
#20
INSTALLATION
#12
SHIELDED SINGLE
#20
CONDUCTOR CABLE
#16
CABLE SHIELD INSTALLATION
SHIELD BRAID
UP TO .15 DIAMETER
.15- .35 DIAMETER
.35 - .75 DIAMETER
BUNDLE FORMING AND
TIE TAPE HEAT-SHRINKABLE
UP TO .30 DIAMETER
PROTECTION
TUBING
.30 - .40 DIAMETER
.40- .80 DIAMETER
SELF-CLINCHING CABLE
1/16 - 1-3/4 INCH DIAMETER
STRAPS FOR USE IN TEMPER-
BUNDLES
ATURES BELOW 850C (185°F)
CIRCULAR CONNECTOR
CONNECTOR CONTACTS
12, 16, 20, 22
REPAIR
SEALING PLUGS
12, 16, 20, 22
MTC FLAT CONNECTOR
MTC FLAT CONNECTOR
20, 22, 24
REPAIR
REPAIR KIT
TERMINAL BOARD REPLACEMENT
TERMINAL BOARD
8 - NO 6 TERMINALS
9-52
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business