Home
Download PDF
Order CD-ROM
Order in Print
Table 9-5. ACMI/BDR Wiring Repair Set Permanent Repair Capabilities (One Hour/One Flight)
CHAPTER 10 FUEL SYSTEM
TM-1-1520-240-BD Army CH-47D Heilcopter (NSN 1520-01-088-3869) (EIC:RCD) Manual
Page Navigation
173
174
175
176
177
178
179
180
181
182
183
TM 1-1520-240-BD
Table 9-5. ACIWBDR Wiring Repair Set Permanent Repair Capabilities (One Hour/One Flight) (Continued)
TYPE OF REPAIR
COMPONENT TO USE
WIRE OR CABLE SIZE
TERMINAL LUG INSTALLATION
TERMINAL LUG (CRIMP-TYPE
24 (4, 6, 8, & 10 STUD)
RING TERMINAL)
22 (6, 8, 10 & 1/4 STUD)
20 (6, 8, 10 & 1/4 STUD)
18 (6, 8, 10 & 1/4 STUD)
16 (6, 8, 10 & 1/4 STUD)
14(6, 8, 10 &1/4 STUD)
UNSHIELDED PRIMARY WIRE
SPLIT BOLT SPLICE
4, 6, 8,10
SPLICING AND REPAIR
CONNECTOR FOR LARGE
WIRE SIZES
CO-AXIAL CABLE SPLICING
CO-AXIAL CABLE SPLICE
RG-9B/U (M17/4)
RG-58C/U (M17/28)
RG-5BJ (M17/29)
RG-71 B/U (M17/90)
RG-124/U
RG-142B/U (M17/60)
RG-179B/U (M1 7/94)
RG-180B/U (M17/95)
RG-214/U (M17175)
RG-223/U (M17/84)
RG-225/U (M17/86)
RG-302/U (M1 7/110)
RG-303/U (M17/111)
RG-316/U (M17/113)
RG-393/U (M171127)
BUNDLE FORMING AND
HEAT-SHRINKABLE REPAIR
PROTECTION
TAPE
CONNECTOR PIN/SOCKET
CRIMP SPLICE WITH PRIMARY
20, 22, 24,16,18 12,14
BY-PASS
WIRE, WIRE REPAIR
SEGMENTS
UNSHIELDED PRIMARY WIRE
CRIMP SPLICE FOR WIRE
20, 22, 24,16,18 12,14
SPLICING AND REPAIR
RATED 1250C OR ABOVE
WIRE REPAIR SEGMENT FOR
20, 22, 24, 16,1812,14
WIRE RATED 1250C OR ABOVE
WIRE OR SHIELDED CABLE
PRIMARY WIRE
#20
INSTALLATION
#12
BUNDLE FORMING AND
NYLON TAPE
SEE NOTE
PROTECTION
CONNECTOR PIN/SOCKET
CRIMP SPLICE WITH PRIMARY
20, 22, 24,16, 18 12, 14
BY-PASS
WIRE, WIRE REPAIR
SEGMENTS
NOTE:
EMERGENCY REPAIRS MAY BE UPGRADED TO PERMANENT REPAIR UPON REMOVAL OF TEFLON
TAPE AND HEAT SHRINKING THE
SPLICE INSULATION
WITH THE HT-9OOA HEAT GUN.
9-53/(9-54 blank)
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business