TM 1-1520-240-CL
E-17/(E-18 blank)
F 3. Rear most ERFS II tank fuel manifold coupling
to FARE pump inlet (top) coupling Connect.
F 4. FARE pump module outlet lower coupling to STA
380 fuel transfer hose Connect.
F 5. T coupling on ERFS II tanks not being
transferred CLOSE.
F 6. FARE valve control handle OFF LOAD
position.
F 7. FARE pump ON.
F 8. ERFS II tank manually operated fuel/defuel
valve OPEN.
F 9. Once ERFS II tank empties, tank fuel manifold
T coupling CLOSE.
F 10. Next ERFS II tank fuel manifold T coupling
OPEN.
F 11. Next/remaining ERFS II tank manually operated
fuel/defuel valve OPEN.
F 12. Once ERFS II tank empties tank fuel manifold
T coupling Close.
F 13. FARE pump OFF.
FARE Pump Failure During Ground FARE Refueling
Operation
F 1. Filters Remove.
F 2. Overwing nozzle Install and use.
F 3. Manually operated fuel/defuel valves OPEN.
F 4. ERFS II tank pumps ON.
EAPS 1 FAIL and/or EAPS 2 FAIL Caution Light ON
1. EAPS DOORS switch (affected engine)
OPEN.
2. EAPS FAIL caution capsule Check OUT.
F 3. EAPS BYPASS DOORS OPEN light Verify
Light is ON.