TM 1-1520-240-CL
E-16
CARGO HOOK EMERG switch REL ALL.
Alternate Method.
F
Forward, center, and aft hook release lever
Pull aft.
HOIST
1. Personnel Clear.
2. CABLE CUTTER switch ON.
ERFS II and FARE
Failure of Fuel Quantity Gauge
F
Remove filler cap from filler opening and look
into tank. Using an explosion proof flashlight or other
sealed beam light source locate fuel tabs which are
attached to inside of column module at calibrated heights,
in increments of 1/4, 1/2. and 3/4. Any tab covered with fuel
will normally not be visible.
No or Slow Fuel Transfer to the Main Tanks
F 1. Manually operated fuel/defuel valve Check
CLOSED.
F 2. UNISEX COUPLINGS Check OPEN.
F 3. Breakaway valves Check OPEN and for
fracture.
F 4. Pumps Check for operation.
F 5. Tank circuit breakers on FUEL CONTROL
PANEL Check reset IN.
F 6. Ensure vent lines connected.
IN FLIGHT Emergency ERFS II Fuel Transfer to Main
Tanks
Using the FARE Fuel pump.
F 1. FARE pump module to rear most ERFS II tank
Install.
F 2. STA 380 fuel transfer hose to rear most ERFS II
tank fuel manifold hose Disconnect.