TM 1-1520-240-CLE-16CARGO HOOK EMERG switch — REL ALL.Alternate Method.FForward, center, and aft hook release lever —Pull aft.HOIST1. Personnel —Clear.2. CABLE CUTTER switch —ON.ERFS II and FAREFailure of Fuel Quantity GaugeFRemove filler cap from filler opening and lookinto tank. Using an explosion proof flashlight or othersealed beam light source locate fuel tabs which areattached to inside of column module at calibrated heights,in increments of 1/4, 1/2. and 3/4. Any tab covered with fuelwill normally not be visible.No or Slow Fuel Transfer to the Main TanksF1. Manually operated fuel/defuel valve — CheckCLOSED.F2. UNISEX COUPLINGS —Check OPEN.F3. Breakaway valves —Check OPEN and forfracture.F4. Pumps —Check for operation.F5. Tank circuit breakers on FUEL CONTROLPANEL —Check reset IN.F6. Ensure vent lines connected.IN FLIGHT Emergency ERFS II Fuel Transfer to MainTanksUsing the FARE Fuel pump.F1. FARE pump module to rear most ERFS II tank— Install.F2. STA 380 fuel transfer hose to rear most ERFS IItank fuel manifold hose —Disconnect.