TM 55-1520-240-PM
PHASE NO. _____
Area Name and No.
Aircraft Serial No.
Date
AFT ROTOR AND PYLON, AREA #6
Inspect
Phase
Nos
Inspection Requirements
Status
Faults and/or Remarks
Action Taken
Initial
ALL/C
6.28 Hydraulic reservoirs, coolers, and
mount structure for cracks, buckling,
and corrosion. Air ducts for security,
cracks, and dents. Access 7, 51
ALL
6.29 Hydraulic lines in pylon hydraulic
compartment for leaks, chafing, and
proper support. Access 7, 51
ALL/C
6.30 Combining transmission housing,
mount lugs, and mount hardware for
loose or missing hardware, cracks,
damage, and corrosion. Adjacent
structure for buckling, damage, cracks,
and loose or missing hardware. Access
40, 42
ALL/C
6.31 Combining and engine
transmission cooling fan exhaust duct
for security, damage, and obstruction.
ALL/C
6.32 Combining and engine
transmission oil coolers for leaks,
clogged or damaged core, and foreign
objects. Cooler housing for cracks and
corrosion. Transfer tubes for damage.
Oil pressure switches/transducer for
condition.
"FOD REMINDER"
Check work area for tools and parts after completion of maintenance and inspection.
2-41