POWER ON CHECKS
Inspect
Phase
Nos
Inspection Requirements
Status
Faults and/or Remarks
Action Taken
Initial
POWER ON CHECKS
WARNING
Before performing each power on
check, make sure all personnel
and equipment are clear of the
system(s) being tested. The aircraft
must be clear of all obstructions or
injury to personnel or damage to
aircraft may result.
ALL
P.1 Perform a preventive maintenance
daily (PMD) IAW TM 55-1520-240-PMD
prior to conducting power checks.
ALL
P.2 Perform DC power system
operational check. Refer to TM
55-1520-240-T.
ALL/C
P.3 APU (running). Electrical and
hydraulic power applied. Check APU
for fuel and oil leaks.
ALL/C
P.4 Maintenance panel for proper
pressure and temperature indications,
PUMP FAULT lights off, GROUND
CONTACT lights (if installed) on.
"FOD REMINDER"
Check work area for tools and parts after completion of maintenance and inspection.
2-79