TM 55-1520-240-T
4-10.12 NO. 2 ENGINE MOTORS NORMALLY BUT DOES NOT START
4-10.12
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Personnel Required:
Applicable Configurations:
Aircraft Electrician (2)
With 74
References:
Tools:
TM 55-1520-240-23
Electrical Repairer's Tool Kit,
Equipment Condition:
NSN 5180-00-323-4915
TM 55-1520-240-23:
Multimeter
Battery Connected
Materials:
Electrical Power On
None
Hydraulic Power Off
END OF TASK
4-242 Change 17