TM 55-1520-240-T
FAILURE SYMPTOM LIST
UTILITY HYDRAULIC SYSTEM
SYMPTOM
TASK
APU OR UT PUMP FAULT LIGHT IS ON
7-2.4
HYDRAULICS OIL LEVEL CIRCUIT BREAKER WILL NOT STAY
CLOSED
7-2.4
HYDRAULIC PWR XFR CIRCUIT BREAKER WILL NOT STAY
CLOSED
7-2.4
HYDRAULICS UTILITY BLOWER CIRCUIT BREAKER WILL
NOT STAY CLOSED
7-2.4
NO. 1 AND NO. 2 HYD FLT CONTR (WITHOUT 74) OR HYD
1 AND HYD 2 (WITH 74) CAPSULES ON WITH POWER XFR
SWITCHES ON
7-2.4
NO. 1 OR NO. 2 HYD FLT CONTR (WITHOUT 74) OR HYD
1 OR HYD 2 (WITH 74) CAPSULE IS ON, SYSTEM
PRESSURIZED
7-2.4
SYMPTOM
TASK
NO. 1 OR NO. 2 HYD FLT CONTR (WITHOUT 74) OR HYD 1
OR HYD 2 (WITH 74) CAPSULE COMES ON WHEN COCKPIT
CONTROLS ARE MOVED
7-2.4
NO. 1 OR NO. 2 HYD FLT CONTR (WITHOUT 74) OR HYD 1
OR HYD 2 (WITH 74) CAPSULE IS ON WITH POWER XFR
SWITCHES ON
7-2.4
PTU PRESSURE LINE PRESSURIZED WHEN ITS SYSTEM
CONTROLS ARE TURNED OFF
7-2.4
UTIL HYDRAULIC COOLING BLOWER CIRCUIT BREAKER
WILL NOT STAY CLOSED
7-2.4
UTILITY HYDRAULIC SYSTEM CAPSULE DOES NOT GO OUT
OR PRESSURE INDICATION IS NOT BETWEEN 3200 AND
3500 PSI WITH APU RUNNING
7-2.4
SYMPTOM
TASK
UTIL HYDRAULIC SYSTEM CAPSULE OUT WHEN SYSTEM
NOT PRESSURIZED
7-2.4
UTILITY HYDRAULICS TEMPERATURE INDICATOR EXCEEDS
95°C
7-2.4
UTILITY PRESS FILTER, UTILITY RTN FILTER, APU PUMP
FAULT OR UT PUMP FAULT LIGHT DOES NOT COME ON
WHEN PRESSED
7-2.4
UTILITY PRESS OR UTILITY RTN FILTER CHANGE LIGHT IS
ON
7-2.4
UTILITY RESERVOIR LEVEL INDICATOR POINTER DOES
NOT INDICATE FLUID LEVEL
7-2.4
CARGO RAMP AND DOOR
SYMPTOM
TASK
CARGO DOOR DOES NOT EXTEND
7-3.4
CARGO DOOR DOES NOT RETRACT
7-3.4
RAMP CONTINUES TO CLOSE AS CARGO DOOR IS EX-
TENDING
7-3.4
SYMPTOM
TASK
RAMP CREEPS WITH RAMP CONTROL VALVE HANDLE AT
STOP
7-3.4
RAMP DOES NOT MOVE DOWN (RAMP IN CLOSED POSITION)
7-3.4
SYMPTOM
TASK
RAMP DOES NOT MOVE UP
7-3.4
RAMP MOVES WITH RAMP SWITCH AT OFF
7-3.4
UTIL SYS CONT CIRCUIT BREAKER DOES NOT STAY
CLOSED
7-3.4
EMERGENCY CARGO RAMP AND DOOR
EXTENSION SYSTEM (WITH 65)
SYMPTOM
TASK
RAMP CONTROL VALVE DOES NOT OPERATE AS SELECTED
FROM RAMP EMER SWITCH
7-3.4.1
RAMP CONTROL VALVE SOLENOIDS DO NOT ENGAGE AND
RAMP CONTROL VALVE HANDLE IS NOT RESTRICTED IN
STOP POSITION WHEN RAMP PWR SWITCH IS SET TO
EMERG
7-3.4.1
SYMPTOM
TASK
RAMP EMERG CONT CIRCUIT BREAKER DOES NOT STAY
CLOSED
7-3.4.
SWIVEL LOCKS SYSTEM
SYMPTOM
TASK
BRAKE STEER CIRCUIT BREAKER DOES NOT STAY
CLOSED
7-4.4
LEFT RIGHT, OR BOTH AFT LANDING GEAR NOT LOCKED
7-4.4
SYMPTOM
TASK
SWIVEL LOCKS, POWER STEERING, AND WHEEL BRAKES
CANNOT BE ISOLATED FROM UTILITY SYSTEM
7-4.4
7-2.2 Change 17