TM 55-1520-240-T7-6.9 PARK BRAKE (WITHOUT 74 ) OR PARK BRK (WITH 74 ) ON CAUTION LIGHT DOES NOT COME ON7-6.9FAULT ISOLATION PROCEDUREINITIAL SETUPReferences:Applicable Configurations:TM 55-1520-240-23AllEquipment Condition:Tools:TM 55-1520-240-23:Electrical Repairer's Tool Kit,Battery ConnectedNSN 5180-00-323-4915Electrical Power OnMultimeterHydraulic Power OnAircraft Jacks RemovedMaterials:NonePersonnel Required:Aircraft ElectricianGO TO NEXT PAGEChange 17 7-190.1/(7-190.2 blank)