TM 55-1520-240-T7-6.117-6.11 UNABLE TO APPLY BRAKES THREE TIMES ON BRAKEACCUMULATOR PRESSUREFAULT ISOLATION PROCEDUREINITIAL SETUPPersonnel Required:Medium Helicopter Repairer (2)References:TM 55-1520-240-23Applicable Configurations:AllSTART APU. DOES UTILITY HYDPRESS INDICATOR REACH3000 PSI?REPLACE AIR VALVE ON ACCU-MULATOR.Equipment Condition:TM 55-1520-240-23Battery ConnectedElectrical Power OnHydraulic Power OnAircraft Jacks RemovedTools:Aircraft Mechanic’s Tool Kit,NSN 5180-00-323-4692REFER TO TROUBLE SYMPTOMTASK 7-8.4.M a t e r i a l s:NonePERFORM LEAK CHECK WITHSOAP AND WATER ON ACCU-MULATOR GAGE. IS GAGELEAKING?CHECK ACCUMULATOR AIRSHUT DOWN APU. DOESBRAKE ACCUMULATOR (25 CU.IN) HOLD 1400 PSI?PRECHARGE. DOES PRE-CHARGE HOLD AT 600 TO 800PSI?REFER TO TROUBLE SYMPTOMTASK 7.6.12.REPLACE GAGE ON ACCUMU-LATOR.BLEED OFF PRESSURE AT AMASTER BRAKE CYLINDER.DISCONNECT AND CAP OFFPRESSURE LINE TO ALL FOURMASTER BRAKE CYLINDERS.PRESSURIZE SYSTEM. THENSHUT DOWN APU DOESBRAKE ACCUMULATOR HOLD1400 PSI?ISOLATE FAULT TO A MASTERBRAKE CYLINDER. CONNECTCYLINDERS ONE AT A TIME TOSYSTEM. PRESSURIZE SYSTEM,THEN SHUT DOWN APU. RE-PLACE CYLINDER THATCAUSES ACCUMULATORPRESSURE TO DROP.REPLACE CHECK VALVEBETWEEN ACCUMULATORAND POWER CONTROLMODULE.45 x 54D145-9658-SPAEND OF TASK7-194Change 1