TM 55 2840-254-23
TM 1-2840-265-23
TASK 8-6.7
TASK 8-6.7.1
TM 55-1520-240-T
8-6.11 NO. 2 POINTER ON PILOTS AND COPILOTS TORQUE INDICATOR OPERATES ERRATICALLY
8-6.11
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Aircraft Powerplant Repairer
Applicable Configurations:
References:
All
TM 55-1520-240-23
Tools:
TM 55-2840-254-23 (Without 74)
Aircraft Powerplant Repairer's Tool Kit,
TM 1-2840-265-23 (With 74
NSN 5180-00-323-4944
On Wing Torque Comparator Test Set Manual,
Electrical Repairer's Tool Kit,
Lycoming Document GSE28295-01 (Without 74)
NSN 5180-00-323-4915
Electric Torquemeter Flight Line Test Set Manual,
On Wing Torque Comparator Test Set LTCT 28295-01
SE-876-1-1006 (With 74)
(Without 74)
Equipment Condition:
Electric Torquemeter Flight Line Test Set
TM 55-1520-240-23:
LTCT 29089-01/-03 (With 74)
Battery Disconnected
Materials:
Electrical Power Off
None
Hydraulic Power Off
Personnel Required:
Nose Access Door Open
Aircraft Electrician
END OF TASK
Change 19 8-120.5/(8-120.6 blank)