T M 5 5 - 1 5 2 0 - 2 4 0 -T
8 - 1 2 . 5 C R U I S E G U I D E I N D I C A T O R P O I N T E R N O T I N T E S T B A N D
W I T H C G I T E S T S W I T C H A T A F T
8 - 1 2 . 5
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairers Tool Kit,
NSN 5180-00-323-4915
Multimeter
Materials:
None
Personnel Required:
68F10 Aircraft Electrician
68F20 Aircraft Electrician
References:
TM 55-1520-240-23
Equipment Condition:
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Hydraulic Power Off
8 - 3 0 2