COPILOTS ROTOR TACHOMETER DOES NOT READ 98 TO 101 PERCENT (Continued)
PILOTS ROTOR TACHOMETER DOES NOT READ 98 TO 101 PERCENT (Continued)
TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
381
382
383
384
385
386
387
388
389
390
391
TM 55-1520-240-T
8-15.6 PILOT’S ROTOR
TACHOMETER
DOES NOT READ 98 TO 101 PERCENT
8-15.6
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairer’s Tool Kit,
NSN
5180-00-323-4915
Multimeter
Materials:
None
Personnel Required:
Aircraft Electrician
References:
TM 55-1520-240-23
Equipment Condition:
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Hydraulic Power Off
8 - 3 40
Change 2