MASTER CAUTION PANEL WIRING DIAGRAM (AVIM)
MASTER CAUTION PANEL FAILS AVIM TEST CONT.
TM-55-1520-240-T-2 CH-47D Heilcopter Manual
Page Navigation
864
865
866
867
868
869
870
871
872
873
874
TM 55-1520-240-T
9-21.3 MASTER CAUTION PANEL FAILS AVIM TEST
9-21.3
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
Personnel Required:
Applicable Configurations:
Aircraft Electrician
Without
74
References:
Tools:
TM 55-1520-240-23
Electrical Repairer's
Tool Kit,
Equipment Condition:
NSN 5180-00-323
-4915
TM 55-1520-240-23:
Multimeter
Master Caution Panel Disconnected from Test
Materials: