TM 55-1520-240-T
10-2.19 RH FUEL PUMP CONT AUX FWD CIRCUIT
BREAKER WILL NOT STAY CLOSED
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairer’s Tool Kit,
NSN
5180-00-323-4915
Multimeter
Materials:
None
Personnel Required:
Aircraft Electrician (2)
References:
TM 55-1520-240-23
Equipment Condition:
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Hydraulic Power Off
Side Acoustical Blanket Removed Between
Sta 320 and 360
10-2.19