TM 55-1520-240-T
10-2.20 LEFT OR RIGHT SIDE AUX PRESS LlGHTS
DOES NOT COME ON WHEN PRESSED TO TEST
10-2.20
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairers Tool Kit,
NSN 5180-00-323-4915
Multimeter
Materials:
None
Personnel Required:
68F20 Aircraft Electrician
References:
TM 55-1520-240-23
Equipment Condition:
TM 55-1520-240-23
Battery Connected
Electrical Power On
Hydraulic Power Off
GO TO NEXT PAGE
10-78