TM 55-1520-240-T
10-2.25 R FUEL PRESS CAPSULE DOES NOT GO OUT WHEN RIGHT SIDE MAIN AFT FUEL PUMPS SWITCH IS SET TO ON
10-2.25
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Equipment Condition:
Applicable Configurations:
TM 55-1520-240-10
All
Both Engines Shut Down
Tools:
TM 55-1520-240-23:
Electrical Repairer's Tool Kit,
Battery Connected
NSN 5180-00-323-4915
Electrical Power On
Multimeter
Hydraulic Power Off
Materials:
Side Acoustical Blanket Removed Between Sta
320 and 360
None
Right Side Intertank Access Panel Open
Personnel Required:
Aircraft Electrician (2)
References:
TM 55-1520-240-10
TM 55-1520-240-23
GO TO NEXT PAGE
10-94 Change 23