TM 55-1520-240-T10-2.26LEFT SIDE AUX PRESS LIGHT COMES ON WHEN LEFT SIDE AFT AUX FUEL PUMP SWITCH IS10-2.26SET TO ONFAULT ISOLATION PROCEDUREINITIAL SETUPReferences:TM 55-1520-240-23Applicable Configurations:AllEquipment Condition:TM 55-1520-240-23:ToolsBattery ConnectedElectrical Repairer's Tool Kit,Electrical Power OnNSN 5180-00-323-4915Hydraulic Power OffSide Acoustical Blanket Removed Between StaMaterials:320 and 360NoneLeft Aft Intertank Access Panel OpenPersonnel Required:Aircraft Electrician (2)GO TO NEXT PAGE10-98 Change 3