TM 55-1520-240-T
10-2.26
LEFT SIDE AUX PRESS LIGHT COMES ON WHEN LEFT SIDE AFT AUX FUEL PUMP SWITCH IS
10-2.26
SET TO ON
FAULT ISOLATION PROCEDURE
INITIAL SETUP
References:
TM 55-1520-240-23
Applicable Configurations:
All
Equipment Condition:
TM 55-1520-240-23:
Tools
Battery Connected
Electrical Repairer's Tool Kit,
Electrical Power On
NSN 5180-00-323-4915
Hydraulic Power Off
Side Acoustical Blanket Removed Between Sta
Materials:
320 and 360
None
Left Aft Intertank Access Panel Open
Personnel Required:
Aircraft Electrician (2)
GO TO NEXT PAGE
10-98 Change 3