Order in Print
PILOTS WINDSHIELD DOES NOT GET WARM (Continued) - TM-55-1520-240-T-3_544
FIRE DETECTION SYSTEM
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
485
486
487
488
489
490
491
492
493
494
495
TM 55-1520-240-T
12-1.15 PILOT’S WINDSHIELD CONTINUES TO HEAT WHEN PLT
WINDSHIELD SWITCH IS AT OFF
FAULT ISOLATION PROCEDURE
IN ITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairer’s Tool Kit,
N S N 5 1 8 0 - 0 0 - 3 2 3 - 4 9 15
Multimeter
Materials:
None
Personnel Required:
68F20 Aircraft Electrician
References:
T M 5 5 - 1 5 2 0 - 2 4 0 - 23
Equipment Condition:
T M 5 5 - 1 5 2 0 - 2 4 0 - 2 3:
Battery Connected
Electrical Power On
Hydraulic Power Off
Nose Dynamic Absorber Removed
12-1.15
12-28
END OF TASK