TM 55-1520-240-T12-2.4 FIRE DETECTION SYSTEM OPERATIONAL CHECK12-2.4INITIAL SETUPReferences:Applicable Configurations:TM 55-1520-240-23AllEquipment Condition:Tools:TM 55-1520-240-23:NoneBattery ConnectedMaterials:Electrical Power OnNoneHydraulic Power OffVisual Check of Fire Detection System PerformedPersonnel Required:(Task 12-2.3)Aircraft ElectricianTASKRESULT1.Check that ENGINE NO. 1 FIRE DET circuit breakerIf ENGINE NO. 1 FIRE DET circuit breaker (1) is open,(1)is closed.close it. If it opens again, go to task 12-2.5.2.Check that ENGINE NO. 2 FIRE DET circuit breakerIf ENGINE NO. 2 FIRE DET circuit breaker (2) is open,(2)is closed.close it. If it opens again, go to task 12-2.5.3.Check NO. 1 ENGINE and NO. 2 ENGINE fire handlesIf either fire handle (3 or 4) caption FIRE PULL/FUEL(3 and 4).SHUTOFF is lit, go to task 12-2.6 or 12-2.7.4.Set and hold FIRE DETECTOR switch (5) to TEST.FIRE PULL/FUEL SHUTOFF captions in NO. 1 ENGINEand NO. 2 ENGINE fire handle (3 and 4) shall light. If bothcaptions do not come on, go to task 12-2.8. If eithercaption does not come on, go to task 12-2.9 or 12-2.10.5.Release FIRE DETECTOR switch (5).Both FIRE PULL/FUEL SHUTOFF captions in NO. 1ENGINE and NO. 2 ENGINE fire handles (3 and 4) shallgo out. If both captions do not go out, replace FIREDETECTOR switch (5).FOLLOW-ON MAINTENANCE:TM 55-1520-240-23:Electrical power off.Battery disconnected.END OF TASKChange 23 12-34.1/(12-34.2 blank)
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business