ENGINE FUEL VALVE HANDLE IS NOT AT OPEN WITH FIRE HANDLE IN (Continued)
ENGINE FUEL VALVE LIGHT DOES NOT COME ON, VALVE OPERATION NORMAL (Continued)
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
20
21
22
23
24
25
26
27
28
29
30
10-20
TM 55-1520-240-T
10-1.10 ENGINE FUEL VALVE LIGHT DOES NOT COME ON,
VALVE OPERATION NORMAL
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairer’s Tool Kit,
NSN
5180-00-323-4915
Multimeter
Personnel Required:
68F20 Aircraft Electrician
References:
TM 55-1520-240-23
Equipment Condition:
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Hydraulic Power Off
10-1.10
Materials:
None