ENGINE FUEL VALVE LIGHT DOES NOT COME ON, VALVE OPERATION NORMAL (Continued)
ENGINE FUEL VALVE HANDLE IS NOT AT CLSD WITH FIRE HANDLE PULLED (Continued)
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
22
23
24
25
26
27
28
29
30
31
32
TM 55-1520-240-T
10-1.11 ENGINE FUEL VALVE HANDLE IS NOT AT CLSD
WITH FIRE HANDLE PULLED
10-1.11
FAULT ISOLATION PROCEDURE
Personnel Required:
INITIAL SETUP
68F20 Aircraft Electrician
Applicable
Configurations:
References:
All
TM 55-1520-240-23
Tools:
Electrical Repairer’s Tool Kit,
NSN
5180-00-323-4915
Equipment Condition:
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Hydraulic Power Off
Multimeter
Materials:
None