TM 55-1520-240-T
14-1.9 CABLE DOES NOT REEL OUT WHEN WINCH IS CONTROLLED BY
WINCH CONTROL GRIP AT STA 95 AUXILIARY PANEL
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Equipment Condition:
Applicable Configurations:
T M 5 5 - 1 5 2 0 - 2 4 0 - 2 3:
All
Battery Connected
Electrical Power On
Tools:
Hydraulic Power On
Electrical Repairers Tool Kit,
N S N 5 1 8 0 - 0 0 - 3 2 3 - 4 9 15
General Safety Instructions:
Multimeter
Asbestos Gloves (E187)
Materials:
Wear gloves when handling wire
None
rope (cable). Otherwise injury to
hands can result.
Personnel Required:
NOTE
68F10 Aircraft Electrician
68F20 Aircraft Electrician
Have helper keep tension on wire
rope (cable) when reeling cable. Ca-
ble will reel evenly and will not snarl
References:
T M 5 5 - 1 5 2 0 - 2 4 0 - 23
Helper must wear gloves.
14-1.9
14-24