ESU BITE INDICATORS DO NOT CYCLE AFTER APU SWITCH SET TO RUN (Continued)
APU FUEL BOOST PUMP CANNOT BE HEARD OPERATING BEFORE APU SWITCH SET TO START (Continued)
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
645
646
647
648
649
650
651
652
653
654
655
TM 55-1520-240-T
15-2.9 APU FUEL BOOST PUMP CANNOT BE HEARD OPERATING BEFORE APU SWITCH SET TO START
15-2.9
FAULT ISOLATION
PROCEDURE
INITIAL SETUP
Personnel Required:
Aircraft Electrician (2)
Applicable Configurations:
All
References:
TM 55-1520-240-23
Tools:
TM 55-1500-343-23
Electrical Repairer's Tool Kit.
NSN
5180-00-323-4915
Equipment Condition:
Multimeter
TM 55-1520-240-23:
Battery Connected
Materials:
Electrical Power On
None
Hydraulic Power Off
GO TO NEXT PAGE
15-36 Change 10
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business