APU ON CAPSULE GOES OUT (APU SHUTS DOWN) WHEN APU CONT CIRCUIT BREAKER OPENED
APU DOES NOT STOP. ESU BITE INDICATES (cont)
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
650
651
652
653
654
655
656
657
658
659
660
T M 5 5 - 1 5 2 0 - 2 4 0 -T
15-2.12 APU DOES NOT STOP.
ESU BITE INDICATES
FAULT ISOLATION PROCEDURE
INITIAL SETUP
References:
TM 55-1520-240-23
TM 55-2835-205-23
Applicable Configurations:
All
Equipment Condition:
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Hydraulic Power Off
Tools:
Aircraft Mechanic’s Tool Kit.
NSN
5180-00-323-4692
Electrical Repairer’s Tool Kit.
NSN
5180-00-323-4915
Multimeter
General Safety Instructions:
Materials:
Cloth (E120)
Tape (E385)
All regulations and instructions
handling fuels shall be strictly
observed.
Personnel Required:
Aircraft Electrician
Medium Helicopter Repairer
15-42
Change 8