RELEASE SW FAIL LIGHT OR GROUND RELAY ACTIVATE LIGHT NOT ON WHEN PILOT CARGO HOOK RELEASE SWITCH PRESSED (Continued)
RELEASE SW FAIL LIGHT OR GROUND RELAY ACTIVATE LIGHT NOT ON WHEN HOIST 1 6 - 1 . 20 OPERATORS CARGO HOOK RELEASE SWITCH PRESSED
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
798
799
800
801
802
803
804
805
806
807
808
TM 55-1520-240-T
16-1.19 RELEASE SW FAIL LIGHT OR GROUND
RELAY
ACTIVATE LIGHT NOT ON WHEN COPILOT’S CARGO
HOOK RELEASE SWITCH PRESSED
16-1.19
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable
All
Tools:
Personnel Required:
Configurations:
68F20 Aircraft Electrician
References:
T M 5 5 - 1 5 2 0 - 2 4 0 - 23
Electrical Repairer’s Tool Kit,
N S N 5 1 8 0 - 0 0 - 3 2 3 - 4 9 15
Multimeter
Materials:
None
Equipment Condition:
T M 5 5 - 1 5 2 0 - 2 4 0 - 2 3:
Battery Disconnected
Electrical Power Off
Hydraulic Power Off
END OF TASK