T M 5 5 - 1 5 2 0 - 2 4 0 - T16-1.20 RELEASE SW FAIL LIGHT OR GROUND RELAY ACTIVATE LIGHT NOT ON WHEN HOIST1 6 - 1 . 20OPERATOR’S CARGO HOOK RELEASE SWITCH PRESSEDFAULT ISOLATION PROCEDUREINITIAL SETUPApplicable Configurations:A l lTools:Electrical Repairer’s Tool Kit,N S N 5 1 8 0 - 0 0 - 3 2 3 - 4 9 1 5M u l t i m e t erMaterials:N o nePersonnel Required:Aircraft ElectricianReferences:T M 5 5 - 1 5 2 0 - 2 4 0 - 2 3Equipment Condition:T M 5 5 - 1 5 2 0 - 2 4 0 - 2 3:B a t t e r y C o n n e c t e dElectrical Power OnHydraulic Power OffG O T O N E X T P A G E1 6 - 50Change 10