Google+
Facebook
LinkedIn
Twitter
Digg
StumbleUpon
Home
Download PDF
Order CD-ROM
Order in Print
LH FUEL PUMPS MAIN FWD CIRCUIT BREAKER WILL NOT STAY CLOSED (Continued)
LH FUEL PUMPS MAIN AFT CIRCUIT BREAKER
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
48
49
50
51
52
53
54
55
56
57
58
TM 55-1520-240-T
10-2.5 LH FUEL PUMPS MAIN AFT
CIRCUIT BREAKER
WILL NOT STAY CLOSED
10-2.5
FAULT /SOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairer’s Tool Kit,
NSN
5180-00-323-4915
Multimeter
Materials:
None
References
TM 55-1520-240-23
Equipment Condition:
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Hydraulic Power Off
Side Acoustical Blanket Removed Between Sta
320 and 360
Left Aft Intertank Access Panel Open
Personnel Required:
Aircraft Electrician (2)
10-48
Change 3
GO TO NEXT PAGE
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business