TM 1-1520-240-CLP-98. Restore the M-1 switch to ON.9. Repeat (7) and (8) above for the M-2, M-3/A andM-C mode switches.10. Place the ANT switch TOP.11. Repeat (7), (8), and (9) above.12. Place the ANT switch DIV.13. Repeat (7), (8), and (9) above.NOTEIf KIT1C is not installed or keyed the followingsteps are not required.14. Set the MODE 4 rotary switch to A. If theexternal computer is used, set a code in it.15. Set the MODE 4 AUDIO/LIGHT/OUT switch toOUT.16. Hold the MODE 4 TEST/ON/OUT switch toTEST.17. If the computer is used, observe that the TESTGO indicator lights. If the computer is notconnected, observe that the TEST/MON/NOGO indicator lights and the KIT STATUSindicator lights.18. Observe that the MODE 4 REPLY light andCAUTION light (on a separate “panel”) do notlight.19. Restore the MODE 4 TEST/ON/OUT switch toON for computer use, or to OUT if no computeris used.