TM 1-1520-240-MTF4-11p. Operate the winch to reel in the cable.Check that the overload-limit switch stopsthe winch when the second layer of thecable wraps start on the cable drum. If winchdoes not stop operating on the second layerof cable, adjust the overload-limit switch andrepeat this step. (Refer to TM55-1520-240-23, Ch. 14.)q. Check the winch for leakage of the hydraulicoil lubricating grease from the housing. Ifother than minor seepage is noted, replacethe winch.r. Stow the winch cable and its relatedequipment. Set the HOIST MASTER switchin the cockpit to OFF. Shut down the apu.(Refer to TM 55-1520-240-23, Ch. 14.)s. Troubleshooting. (Refer to TM55-1520-240-23.)E. LOOSENESS CHECK.1-30.Reference:TM 55-1520-240-23WARNINGKeep head, hands and other body parts clearof moving flight controls. Hydraulic forcesare strong enough to cause sever injury.NOTEImpedance bolts have been installed in flight con-trol connections. These bolts are self-retainingand require a special nut and torque. Refer tochapter 1 of reference for information on the bolts.