TM 1-1520-240-MTF2-57ENGINE RUN UP (CONT.) b. L AFT MAIN FUEL PUMP switch — ON.Check L and R Fuel Press caution capsulesshould go out. Then switch OFF.c. Remaining MAIN FUEL PUMP switches —Check as in step b. above.d. Left AFT AUX FUEL PUMP switch — ON.Check L AFT AUX — Press light comes onthen goes out. Set FUEL PUMP switch toOFF.e. Remaining three AUX FUEL PUMP —Check as in step d, except check R AUXpress light on, then off, for R AUX FUELPUMP switches.F f. CROSSFEED switch — Closed. Checkclosed.g. Either LEFT MAIN FUEL PUMP ON —Check only left fuel pressure caution lightout. LEFT MAIN FUEL PUMP switch OFF.h. Check RIGHT MAIN FUEL PUMP in samefashion as in steps b. through d. above.B*5. ALL FUEL CONTR Switches — Set.B6. VGI switches — As required.7. XMSN OIL PRESS and TEMP IndicatorOperation.a. Check individual XMSN OIL PRESSreadings. Allowable fluctuation of oilpressure readings shall not exceed $ 10%of actual readings.b. XMSN OIL PRESS — SCAN. Reading $ 3psi of low transmission.c. XMSN OIL PRESS — TEST. Check to 0 psior below.d. XMSN OIL PRESS switch — SCAN.