TM 1-1520-240-MTF
2-61
* B TAXIING (CONT.)
c. Check PWR STEER caution light Out.
(1) Check 10 degree deviation (maximum)
in 100 feet.
(2) SWIVEL switch LOCK, Check 5
degree deviation (maximum in 100 feet.
(3) Check power STEERING CONTROL
inoperative with SWIVEL at LOCK.
B BEFORE HOVER
1-17.
B* 1. Swivel switch Lock.
B* 2. AFCS System control panel Set as follows:
a. AFCS System SEL switch Both.
b. Cyclic Trim Auto.
B 3. 714A FADEC system Check.
a. FADEC RRPM Check.
(1) FADEC NR% switch 97. Check
RRPM decreases to 97% " 1% with
torques matched within 4%.
(2) FADEC NR% switch 103. Check
RRPM increases to 103% " 1% with
torques matched within 4%.
(3) FADEC NR% switch 100. Check
RRPM decreases to 100% " 1% with
torques matched within 4%.
b. FADEC Reversionary Mode Beep Check.
(1) ENG No. 2 ECL GND.
(2) FADEC No. 1 PRI/REV switch REV.
(3) Thrust Control Lever Increase to
obtain 90% N1