TM 55-1520-240-T
6-1.3 TRANSMISSION LUBRICATION SYSTEMS OPERATIONAL CHECK (Continued)
6-1.3
TASK
RESULT
6. Check XMSN TEMP indicator (10).
7.
8.
XMSN AUX OIL PRESS capsule (9) shall go out as
pointer on XMSN OIL PRESS indicator (6) passes 20
psi. If capsule (9) is still on, note which TRANSMIS-
SION AUX OIL PRESS light (12) is on. Have pilot
stop engines, then go to Task 6-1.6.
Pointer on indicator (10) shall be in normal range. If
it is not and XMSN OIL HOT capsule (11) is on, have
pilot stop engines, then go to Task 6-1.7.
Have pilot stop engines.
Check maintenance panel TRANSMIS-
If any indicator (1) is black and white, go to Task 6-
SION CHIP DETECTOR and DEBRIS
2.3. If any indicator (2) is black and white, go to
SCREEN indicators (1 and 2).
Task 6-2.3.
FOLLOW-ON MAINTENANCE:
TM 55-1520-240-23
Shut down engines.
Electrical power off.
Hydraulic power off.
Battery disconnected.
END OF TASK
Change 5
6-11