TM 55-1520-240-T6-1.3 TRANSMISSION LUBRICATION SYSTEMS OPERATIONAL CHECK (Continued)6-1.3TASKRESULT6. Check XMSN TEMP indicator (10).7.8.XMSN AUX OIL PRESS capsule (9) shall go out aspointer on XMSN OIL PRESS indicator (6) passes 20psi. If capsule (9) is still on, note which TRANSMIS-SION AUX OIL PRESS light (12) is on. Have pilotstop engines, then go to Task 6-1.6.Pointer on indicator (10) shall be in normal range. Ifit is not and XMSN OIL HOT capsule (11) is on, havepilot stop engines, then go to Task 6-1.7.Have pilot stop engines.Check maintenance panel TRANSMIS-If any indicator (1) is black and white, go to Task 6-SION CHIP DETECTOR and DEBRIS2.3. If any indicator (2) is black and white, go toSCREEN indicators (1 and 2).Task 6-2.3.FOLLOW-ON MAINTENANCE:TM 55-1520-240-23Shut down engines.Electrical power off.Hydraulic power off.Battery disconnected.END OF TASKChange 56-11