7-2.3 UTILITY HYDRAULIC SYSTEM VISUAL CHECK (Continued)
TASK
RESULT
11. Check utility cooling fan (14).
If fan (14) is loose or damaged, tighten or replace
it as required. If fan screen is clogged, clean it. If
electrical connector to fan is loose or damaged,
tighten or replace it as required. If wiring to con-
nector is damaged, repair or replace it as required.
12. Check duct (15).
13 Check utility reservoir cooler (16).
If duct (15) is loose or torn, tighten or replace it as
required.
If cooler (16) is loose or damaged tighten or re-
place it as required. If any tube to cooler is loose
or damaged, tighten or replace it as required. If
any electrical connector to code is loose or
damaged, tighten or replace it as required. If wir-
ing to connector is damaged, repair or replace it as
required.
7-2.3