TM 55-1520-240-T7-2.3 UTILITY HYDRAULIC SYSTEM VISUAL CHECK (Continued)7-2.3TASKRESULT14. Check No. 2 power transfer unit (17).If No. 2 PTU (17) is loose or damaged, tighten orreplace it as required. If any hose or tube-to-No-2PTU is loose or damaged. tighten or replace it asrequired. If any electrical connector to PTU isloose or damaged, tighten or replace it as re-quired. If wiring to connector is damaged, repair orreplace it as required.15. Check No. 1 power transfer unit (18).If No. 1 PTU (1 8) is loose or damaged, tighten orreplace it as required. If any hose or tube to No. 1PTU is loose or damaged, tighten or replace it asrequired. If any electrical connector to PTU isloose or damaged. tighten or replace it as re-quired. If wiring to connector is damaged, repair orreplace it as required.FOLLOW-ON MAINTENANCE:TM 55-1520-240-23:Pylon Access Doors ClosedRight Forward Work platform ClosedEND OF TASK7-79