9-16.9 RED LIGHTS ON FWDANDAFTTROOP WARNING
BOXES DO NOT GO DIM
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Personnel Required:
68F10 Aircraft Electrician
Applicable Configurations:
All
References:
TM 55-1520-240-23
Tools:
Electrical Repairers Tool Kit,
NSN 5180-00-323-4915
Multimeter
Equipment Condition:
TM 55-1520-240-23:
Electrical Power On
Hydraulic Power Off
Materials:
None
END OF TASK