TM 55-1520-240-T
9-16.10 RED TROOP JUMP LTS LIGHT DOES NOT GO DIM
9-16.10
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Personnel Required:
Aircraft Electrician
Applicable Configurations:
W i t h o u t
References:
TM 55-1520-240-23
Tools:
Electrical Repairers Tool Kit,
NSN 5180-00-323-4915
Multimeter
Materials:
Equipment Condition:
TM 55-1520-240-23:
Battery Connected
Electrical Power On
Hydraulic Power Off
END OF TASK
Change 5
9-295