T M 5 5 - 1 5 2 0 - 2 4 0 - T
9-16.11 GREEN LIGHT ON FWD OR AFT TROOP WARNING
BOX OR TROOP JUMP LTS LIGHT DO NOT
COME ON BRIGHT
FAULT ISOLATION PROCEDURE
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairers Tool Kit,
NSN 5180-00-323-4915
Multimeter
Materials:
None
Personnel Required:
68F10 Aircraft Electrician
68F20 Aircraft Electrician
References:
TM 55-1520-240-23
Equipment Condition:
Battery Connected
Electrical Power On
Hydraulic Power Off
9-16.11
9 - 2 9 6
GO TO NEXT PAGE