HEATING AND VENTILATING SYSTEM OPERATIONAL CHECK (Continued)
CABIN HEATER CONT CIRCUIT BREAKER WILL NOT STAY CLOSED (Continued)
TM-55-1520-240-T-3 CH-47D Heilcopter Manual
Page Navigation
550
551
552
553
554
555
556
557
558
559
560
TM 55-1520-240-T
13-1.5
CABIN HEATER CONT
CIRCUIT BREAKER
WILL
13-1.5
NOT STAY CLOSED
FAULT ISOLATION
PROCEDURE
Personnel Required:
68F20 Aircraft Electrician
INITIAL SETUP
References:
Applicable Configurations:
TM 55-1520-240-23
All
Tools:
Equipment Condition:
Electrical Repairer's Tool Kit.
TM 55-1520-240-20:
NSN
5180-00-323-4915
Battery Disconnected
Multimeter
Electrical Power Off
Hydraulic Power Off
Materials:
Heater Compartment
Acoustic
None
Blanket Removed
GO TO NEXT PAGE
13-8